Skip to content

Consultation on wastewater treatment processes #186

@zasddsgg

Description

@zasddsgg

Hello. I created the wastewater treatment process with the code wwt_sys = create_conventional_wastewater_treatment_system(ins=’’, 'blowdown'], mockup=True). When the system was run twice, error ValueError: <ReverseOsmosis: S604> assignment destination is read-only was reported. May I ask how this should be solved. Thanks for your help.

The detailed error information is as follows:

File D:\anaconda\envs\zddd\lib\site-packages\biosteam\_system.py:2631, in System.simulate(self, update_configuration, units, design_and_cost, **kwargs)
   2611 def simulate(self, update_configuration: Optional[bool]=None, units=None, 
   2612              design_and_cost=None, **kwargs):
   2613     """
   2614     If system is dynamic, run the system dynamically. Otherwise, converge 
   2615     the path of unit operations to steady state. After running/converging 
   (...)
   2629         
   2630     """
-> 2631     with self.flowsheet.temporary():
   2632         specifications = self._specifications
   2633         if specifications and not self._running_specifications:

File D:\anaconda\envs\zddd\lib\site-packages\biosteam\_flowsheet.py:38, in TemporaryFlowsheet.__exit__(self, type, exception, traceback)
     36 def __exit__(self, type, exception, traceback):
     37     main_flowsheet.set_flowsheet(self.original)
---> 38     if exception: raise exception

File D:\anaconda\envs\zddd\lib\site-packages\biosteam\_system.py:2687, in System.simulate(self, update_configuration, units, design_and_cost, **kwargs)
   2681         outputs = self.simulate(
   2682             update_configuration=True, 
   2683             design_and_cost=design_and_cost,
   2684             **kwargs
   2685         )
   2686     else:
-> 2687         raise error
   2688 else:
   2689     if (not update_configuration # Avoid infinite loop
   2690         and self._connections != [i.get_connection() for i in self.streams]):
   2691         # Connections has been updated within simulation.

File D:\anaconda\envs\zddd\lib\site-packages\biosteam\_system.py:2674, in System.simulate(self, update_configuration, units, design_and_cost, **kwargs)
   2672 else:
   2673     try:
-> 2674         outputs = self.converge(**kwargs)
   2675         if design_and_cost: self._summary()
   2676     except Exception as error:

File D:\anaconda\envs\zddd\lib\site-packages\biosteam\_system.py:2374, in System.converge(self, recycle_data, update_recycle_data)
   2372     for i in range(self._N_runs): method()
   2373 else:
-> 2374     method()
   2375 if update_recycle_data:
   2376     try: recycle_data.update()

File D:\anaconda\envs\zddd\lib\site-packages\biosteam\_system.py:2258, in System.run_sequential_modular(self)
   2256 f = try_method_with_object_stamp
   2257 for i in self._path:
-> 2258     if isa(i, Unit): f(i, i.run)
   2259     elif isa(i, System): f(i, i.converge)
   2260     else: raise RuntimeError('path elements must be either a unit or a system')

File D:\anaconda\envs\zddd\lib\site-packages\thermosteam\exceptions.py:94, in try_method_with_object_stamp(object, method, args)
     92     raise StampedKeyError(message_with_object_stamp(object, repr(error.args[0])))
     93 except Exception as error:
---> 94     raise_error_with_object_stamp(object, error)

File D:\anaconda\envs\zddd\lib\site-packages\thermosteam\exceptions.py:84, in raise_error_with_object_stamp(object, error)
     82     error.args = (message_with_object_stamp(object, msg), *args)
     83 except: pass
---> 84 raise error

File D:\anaconda\envs\zddd\lib\site-packages\thermosteam\exceptions.py:88, in try_method_with_object_stamp(object, method, args)
     86 def try_method_with_object_stamp(object, method, args=()):
     87     try:
---> 88         return method(*args)
     89     except StampedKeyError as error:
     90         raise StampedKeyError(message_with_object_stamp(object, error.args[0]))

File D:\anaconda\envs\zddd\lib\site-packages\thermosteam\network.py:1459, in AbstractUnit.run(self)
   1457         if self.run_after_specifications: self._run()
   1458 else:
-> 1459     self._run()

File D:\anaconda\envs\zddd\lib\site-packages\biosteam\wastewater\conventional.py:506, in ReverseOsmosis._run(self)
    504 water_recovered = self.water_recovery * water_flow
    505 water.mol[water_index] = water_recovered
--> 506 brine.mol[water_index] = water_flow - water_recovered

File D:\anaconda\envs\zddd\lib\site-packages\thermosteam\base\sparse.py:1646, in SparseVector.__setitem__(self, index, value)
   1645 def __setitem__(self, index, value):
-> 1646     if self.read_only: raise ValueError('assignment destination is read-only')
   1647     dct = self.dct
   1648     if index.__class__ is tuple:

ValueError: <ReverseOsmosis: S604> assignment destination is read-only