# -- Python-Script-File
# -- Name : ---
# -- Author : National Instruments Ireland Resources Limited
# -- Comment :
# -----------------------------------------------------------------------------
import DIAdem
dd=DIAdem.Application
if False:
import DIAdem_CodeCompletion as dd
sPathDocuments = dd.ProgramDrv + "Examples\\Documents\\"
sPathData = dd.ProgramDrv + "Examples\\Data\\"
# -------------------------------------------------------------------------------
dd.Data.Root.Clear()
dd.DataFileLoad(sPathData + "Resampling.tdm", "TDM", "Load|ChnXYRelation")
oSource = dd.Data.GetChannel("[1]/Signal")
dd.FFTIntervPara[2] = oSource.Size
dd.ChnFFT1("", oSource)
oGroup = dd.Data.Root.ChannelGroups.Add("Result-Resampling")
oGroup.Activate()
oGroupChns = oGroup.Channels
oChnRS200 = oGroupChns.Add("Resampled_200", dd.DataTypeChnFloat64)
oChnRS200.Properties.Add("Sampling_rate_in_Hz", 200, dd.DataTypeFloat64)
oChnRS100 = oGroupChns.Add("Resampled_100", dd.DataTypeChnFloat64)
oChnRS100.Properties.Add("Sampling_rate_in_Hz", 100, dd.DataTypeFloat64)
oChnRS50 = oGroupChns.Add("Resampled_50", dd.DataTypeChnFloat64)
oChnRS50.Properties.Add("Sampling_rate_in_Hz", 50, dd.DataTypeFloat64)
oChnRS10 = oGroupChns.Add("Resampled_10", dd.DataTypeChnFloat64)
oChnRS10.Properties.Add("Sampling_rate_in_Hz", 10, dd.DataTypeFloat64)
for iLoop in range(1,5):
dd.ChnResampleFreqBased("", oSource, oGroupChns(iLoop), oGroupChns(iLoop).Properties("Sampling_rate_in_Hz").Value, "Automatic", 0, 0)
iResampleChnCount = oGroupChns.Count
for iLoop in range(1, iResampleChnCount + 1):
oCurrChn = oGroupChns(iLoop)
dd.FFTIntervPara[2] = oCurrChn.Size
dd.FFTAmplType = "Ampl.Peak"
dd.ChnFFT1("", oCurrChn)
dd.Data.GetChannel("/AmplitudePeak").Name = oCurrChn.Name + "_AmplitudePeak"
dd.Report.LoadLayout(sPathDocuments + "Resampling")
dd.Report.Refresh()
oGroup = dd.Data.Root.ChannelGroups.Add("Result-Resampling_filtered")
oGroup.Activate()
oGroupChns = oGroup.Channels
oChnRS200 = oGroupChns.Add("Resampled_200", dd.DataTypeChnFloat64)
oChnRS200.Properties.Add("Sampling_rate_in_Hz", 200, dd.DataTypeFloat64)
oChnRS100 = oGroupChns.Add("Resampled_100", dd.DataTypeChnFloat64)
oChnRS100.Properties.Add("Sampling_rate_in_Hz", 100, dd.DataTypeFloat64)
oChnRS50 = oGroupChns.Add("Resampled_50", dd.DataTypeChnFloat64)
oChnRS50.Properties.Add("Sampling_rate_in_Hz", 50, dd.DataTypeFloat64)
oChnRS10 = oGroupChns.Add("Resampled_10", dd.DataTypeChnFloat64)
oChnRS10.Properties.Add("Sampling_rate_in_Hz", 10, dd.DataTypeFloat64)
for iLoop in range(1,5):
dd.ChnResampleFreqBased("", oSource, oGroupChns(iLoop), oGroupChns(iLoop).Properties("Sampling_rate_in_Hz").Value, "Automatic", 1, 0)