On CPU clusters, inference throughput depends heavily on which cores a model runs on. A model whose threads are spread across NUMA nodes pays a memory-latency penalty on every token, and a model sharing cores with a noisy neighbour loses throughput unpredictably.
A NUMA node is a group of cores with the memory attached closest to them. Intel® Inference Toolkit pins model pods to physical cores that respect the node's NUMA topology, so each model gets exclusive, locality-aware CPU.
One switch in config.yaml (in your environment:
env/<env>/config.inference.yaml) controls all CPU-pinning infrastructure. Every dependent
setting — NRI install, kubelet flags, model annotations — is derived from it.
kubernetes_cpu_policy: "nri-balloons" # nri-balloons | kubelet-static | best-effort| Policy | Mechanism | Use when |
|---|---|---|
nri-balloons (default) |
NRI balloons resource policy — NUMA-aware pinning into named CPU pools | The default. Best throughput and the most control |
kubelet-static |
kubelet static CPU manager — Guaranteed QoS grants exclusive whole cores | You cannot run NRI, or you already standardized on the static CPU manager |
best-effort |
No pinning; the standard scheduler places threads | Development, oversubscribed nodes, or debugging a pinning problem |
Warning
This must match the value the cluster was installed with. It decides both how kubelet is configured (Toolkit Manager repo) and how model manifests are rendered (this repo). To change it on an existing cluster, follow NRI CPU Balloons in the Toolkit Manager docs.
model-manager records the resolved policy on each model pod:
annotations:
cpu-policy.model-manager.io/type: nri-balloons
cpu-policy.model-manager.io/balloon: model-balloon-tp1Under nri-balloons a model needs a whole number of CPUs. If its cpu is not a whole
number, the pre-flight stops the deploy ("nri-balloons needs a whole number of CPUs").
With MM_PREFLIGHT=warn, MM_SKIP_PREFLIGHT=1 or MM_NRI_ENABLED=false it deploys anyway:
model-manager annotates the pod type: best-effort with reason: nri-resolution-failed
rather than pinning it incorrectly, and the model serves without exclusive cores.
The NRI balloons policy groups CPUs into balloons (named sets of cores) and assigns pods to
them, keeping each pod's cores within one NUMA node where possible. model-manager picks the
balloon type from the model's tensor-parallel size (TP), rounded up to 1, 2, 4 or 8
(model-balloon-tp1 ... -tp8); MM_NRI_BALLOON_NAME=<type> forces one type for a deploy.
Tuning lives in the Toolkit Manager repo, because it configures the nodes (see its NRI CPU Balloons guide):
# nri_reserved_cpu_list: "" # Linux cpuset for system CPUs (auto-sized if empty)
# nri_deployment_profile: "siblings" # siblings | minimal(8) | standard(12) | observability(16) | full(20)The profile sizes the CPU reservation for platform services. The default, siblings,
reserves the second hyperthread of every physical core, so model balloons get physical cores
only. The others hold back the number of logical CPUs in parentheses. Pick a larger profile
when the cluster also runs observability or RAG workloads, so model pods don't contend with
them.
Before changing anything, model-manager deploy verifies the request actually fits:
cpu×replicasagainst the available balloon pool, and- for
--tp N, that the shards can spread across NUMA nodes
If it would oversubscribe, the deploy is blocked (NRI pre-flight failed: not enough physical cores ...) with actionable guidance rather than creating a pod that will never
schedule. The check runs before the weights are downloaded.
| Override | Effect |
|---|---|
MM_PREFLIGHT=warn |
Report the shortfall, then proceed anyway (MM_NRI_PREFLIGHT=warn also works) |
MM_SKIP_PREFLIGHT=1 |
Skip the placement check entirely (MM_NRI_SKIP_PREFLIGHT=1 skips only the NRI part) |
MM_NRI_ENABLED=false |
Legacy: deploy as best-effort, without NRI annotations |
Re-deploying an unchanged model is a no-op: model-manager diffs the rendered spec
server-side and skips both pre-flight and apply when nothing changed, so a running
model's own cores are never counted against it. Set MM_FORCE_REDEPLOY=1 to force a full
re-apply.
A catalog model with cpu: auto takes its CPU from the same balloon data: the free
physical cores of one NUMA node per TP rank, on the smallest schedulable node. A deployed
model keeps the CPU it has. See Model Catalog.
model-manager cpu-collisions-check reports the actual CPU assignment for running model
pods — pod, balloon, node, NUMA node, CPUs, and hyperthread siblings — and flags cores used by
more than one model. It runs model_manager/scripts/nri-cpu-report.py, which needs the
kubernetes Python package (pip install kubernetes):
./model-manager cpu-collisions-checkUnder kubelet-static, model pods are rendered as Guaranteed QoS — integer cpu
with requests equal to limits — so kubelet's static CPU manager grants them exclusive
whole cores.
With the kubelet option full-pcpus-only enabled (the Toolkit Manager default), a pod's cpu request must be a
multiple of the SMT width, or kubelet rejects the pod with SMTAlignmentError.
model-manager rounds cpu up to satisfy this automatically.
On an SMT-disabled cluster, tell it the width is 1:
mm_kubelet_threads_per_core: 1 # exported as MM_KUBELET_THREADS_PER_COREPinning decides which cores; node affinity decides which node. NFD, which the core platform
layer installs (node_feature_discovery), labels every node with its hardware capabilities:
feature.node.kubernetes.io/cpu-cpuid.AMXBF16=true
feature.node.kubernetes.io/cpu-cpuid.AVX512F=true
model-manager turns the AMX label into a required nodeAffinity rule: the catalog's
require_amx: true default keeps model pods off nodes without Intel® AMX
(cpu-cpuid.AMXBF16) — see Model Catalog. Pin a model to
one specific node with --node <name>: optional, but when given the pod runs on that node or
stays Pending.
# Force a policy for one model (must match how the cluster was installed)
./model-manager deploy qwen3-0-6b --cpu-policy best-effort --wait
# Give a model 16 cores, split over 2 NUMA nodes
./model-manager deploy llama3-8b-awq --cpu 16 --tp 2 --wait
# See what would be rendered, including annotations, without applying
./model-manager deploy qwen3-0-6b --dry-runRelated: Configuration · Deploy a Model · Troubleshooting