Brain MRI · Lung CT · Skin lesions — three interpretable classifiers behind one interface, plus a study of what happens when you give a cancer model the wrong kind of image.
⚕️ Research and education only. Not a medical device. Not cleared for clinical or diagnostic use. Cannot diagnose cancer. Do not upload identifiable patient data.
Train a brain-MRI tumour classifier. Show it a chest CT — an image with no brain tissue in it at all. It does not abstain, and it does not hedge:
55.9% of chest CT slices are labelled "tumour" with ≥90% confidence — more than twice the rate at which it makes confident tumour calls on its own test set. Its mean confidence on those foreign images (0.876) is higher than on its own data (0.820).
Silent failure rate — how often a foreign image gets a confident malignant label. Rows = model, columns = where the images actually came from:
| Model ↓ / Input → | Brain | Lung | Skin |
|---|---|---|---|
| Brain | native | 55.9% | 14.7% |
| Lung | 5.3% | native | 0.0% |
| Skin | 0.0% | 0.0% | native |
Exposure is wildly model-dependent: the 7-class skin model shrugs it off, the binary brain model — which has nowhere to put an unfamiliar image except "tumour" or "no tumour" — is catastrophically exposed. You cannot predict this from published accuracy. It has to be measured.
We benchmarked the standard OOD detectors on the same data. FPR@95TPR = how many foreign images still get through when you admit 95% of legitimate ones.
| Detector | AUROC ↑ | FPR@95TPR ↓ |
|---|---|---|
| Modality gate (ours) | 1.000 | 0.0% |
| Mahalanobis | 0.959 | 22.1% |
| kNN | 0.926 | 19.8% |
| MSP (max softmax) | 0.777 | 68.6% |
| Energy | 0.773 | 58.2% |
The cheap guards fail exactly where they're needed. On the brain model — the one actually producing 55.9% false malignancies — MSP scores 0.529 and Energy 0.508, both indistinguishable from a coin flip. "We only show results above 90% confidence" is not a safety measure here. And even Mahalanobis, the best unsupervised detector, still lets 1 in 5 foreign images through.
A modality gate: one small classifier that answers "which modality is this?" before any diagnostic model sees the image. Frozen ImageNet trunk, linear head, 99.94% accurate. If its answer doesn't match the selected task — or it isn't confident — the system refuses instead of diagnosing.
| No gate | With gate | |
|---|---|---|
| Mean silent failure rate | 12.6% | 0.0% |
| Worst-pair silent failure rate | 55.9% | 0.0% |
| Foreign images admitted | 100% | 0.0% |
| Legitimate images admitted | 100% | 100% |
| Accuracy on legitimate inputs | 84.20% | 84.20% |
Zero silent failures, zero measurable cost. It beats every unsupervised detector for a simple reason — not sophistication, but information: an unsupervised score has to infer the boundary of "normal" from one class of data, while a deployment already knows the exact list of modalities it serves. The gate never touches the diagnostic models, so it can be bolted onto an already-validated system.
📄 Full write-up: paper/modality_mismatch.md
Refusing bad inputs makes the system safe. It does not make it useful. The reason a department buys diagnostic AI is not diagnosis — it is triage: removing the clearly-normal studies from a human worklist. That needs a number no accuracy figure contains.
"It removes X% of your list, and of the cancers in what it removes, it misses no more than Y%."
Softmax cannot supply it, and temperature scaling barely helps — on skin it moves ECE only 0.050 → 0.044, because the miscalibration is localised (cases scored ~0.65 are malignant ~40% of the time), not a uniform sharpness error one scalar can absorb. So we stop relying on the score being a probability and put the guarantee on the threshold instead: a Clopper-Pearson upper bound walked over thresholds in a fixed sequence. Distribution-free, finite-sample, and valid even if the calibration is wrong.
Skin — the promise holds:
| Promised miss rate | ≤ 4.96% (95% confidence) |
| Delivered on test | 2.57% (10/389) — sensitivity 97.4% |
| Worklist removed | 38.3% (650/1699) |
| Prevalence, before → after | 22.9% → 36.1% |
| Violations across 50 calibration draws | 0/50 |
What a stricter promise costs:
| Tolerated miss rate | 2% | 5% | 10% | 15% | 20% | 30% |
|---|---|---|---|---|---|---|
| Worklist removed | 2.1% | 38.3% | 56.6% | 62.8% | 66.2% | 71.8% |
| Cancers missed (test) | 0.0% | 2.6% | 8.0% | 12.6% | 15.4% | 21.3% |
A sample-size wall. Promising a 5% miss rate at 95% confidence needs at least
59 malignant calibration cases — n ≥ log δ / log(1−α) — before model
quality enters the argument. Brain has 15 and lung has 41, so despite AUCs of
0.988 and 0.972 neither can support the promise, and the tool clears nothing and
says why. A perfect classifier calibrated on 40 cancers still cannot promise 5%.
An exchangeability wall. The bound assumes deployment cases are exchangeable with calibration cases. Lung's public splits ship as fixed folders, not random draws, and it shows: a threshold promising ≤14.6% misses delivered 31.9%. The bound wasn't wrong — its precondition was. That specific failure is detectable without labels, which is the situation at any new site on day one:
| Task | KS | p | verdict |
|---|---|---|---|
| Lung | 0.364 | 2.4 × 10⁻⁷ | shift — guarantee void |
| Brain | 0.132 | 0.90 | consistent |
| Skin | 0.030 | 0.42 | consistent |
The check is a precondition, not a footnote: when it fires the app reports the guarantee as void and refuses to auto-clear.
The gate stops a failure of commission — a confident label on an image the model should never have seen. This stops a failure of omission — a case silently cleared and never read. A triage deployment creates the second one, so both guards are needed, and neither touches the diagnostic model.
📄 Full write-up: paper/rule_out_triage.md
Ordinary transfer-learning baselines — the point of this repo is the study above, not a leaderboard entry.
| Task | Modality | Classes | Test accuracy | Macro AUC |
|---|---|---|---|---|
| Brain | MRI | tumour / no tumour | 89.5% | 0.988 |
| Lung | CT | 3 carcinoma subtypes + normal | 87.8% | 0.972 |
| Skin | Dermatoscopy | 7 lesion types | 80.5% | 0.962 |
Lung, per class: normal is separated essentially perfectly (sensitivity 98.2%, specificity 100%, AUC 0.9998); the three carcinoma subtypes are harder to tell apart from each other (AUC 0.943–0.976), which is the clinically expected pattern.
Both fixes lower the headline numbers. That is the point.
- Brain — the archive ships a nested duplicate copy of every image. Split naively and the same image lands on both sides. We de-duplicate on filename first.
- Skin — HAM10000 contains several photographs of the same lesion, and the
splits shipped with the popular HF mirror are drawn at image level:
72.4% of the test lesions also appear in train. Training on those splits gives
94.4% accuracy / 0.997 AUC — comfortably above published state of the art for
7-class HAM10000, which is the tell. We re-split on
lesion_id, which gives the honest 80.5% / 0.962 above.
If you benchmark against this mirror's default splits, your numbers are not comparable to the literature.
git clone https://github.com/aliaht99/OncoAI.git
cd OncoAI
pip install -r requirements.txt
./run.shBundled demo images mean you need no dataset to see it work — pick one from
demo_images/ in the sidebar. Then deliberately feed a lung CT to the brain model
and watch the gate refuse.
# 1. Public datasets — no account, no API key
python src/common/download_data.py # or: brain lung skin
# 2. Train the three diagnostic models
python src/common/train.py brain
python src/common/train.py lung
python src/common/train.py skin
# 3. Per-task evaluation: metrics, ROC, confusion matrix, Grad-CAM
python src/common/evaluate.py brain
# 4. The study
python src/novel/modality_audit.py --tau 0.9 # measure the failure
python src/novel/modality_gate.py train # build the guard
python src/novel/modality_gate.py evaluate # measure the fix
python src/novel/ood_baselines.py # vs MSP / Energy / Mahalanobis / kNN
python src/novel/make_figures.py
# 5. the triage study
python src/novel/triage.py # all three tasks
python src/novel/triage.py --task skin --trials 50 # re-draw the calibration split
python src/novel/triage.py --alpha 0.10 # a looser promiseOncoAI/
├── app.py Streamlit app — all three tasks + live gate
├── run.sh one-command launcher
├── src/
│ ├── common/
│ │ ├── download_data.py fetch the three public datasets
│ │ ├── data.py per-task dataset builders
│ │ ├── model.py shared backbone + head
│ │ ├── train.py two-phase transfer learning
│ │ ├── evaluate.py metrics, ROC, confusion, Grad-CAM
│ │ └── make_demo_images.py sample images for the app
│ └── novel/
│ ├── modality_audit.py cross-modality silent-failure audit
│ ├── modality_gate.py the gate: train + evaluate
│ ├── ood_baselines.py MSP / Energy / Mahalanobis / kNN comparison
│ ├── triage.py calibration + bounded rule-out threshold
│ └── make_figures.py paper figures
├── models/ trained weights + metrics JSON
├── results/
│ ├── brain|lung|skin/ per-task figures and metrics
│ └── novel/ audit + gate results and figures
├── paper/
│ ├── modality_mismatch.md write-up: silent failure + the gate
│ └── rule_out_triage.md write-up: bounded worklist reduction
└── demo_images/ sample images, no dataset needed
All public, all fetched by the script above, none redistributed here.
| Task | Source |
|---|---|
| Brain | Brain MRI Images for Brain Tumor Detection |
| Lung | Chest CT-Scan images |
| Skin | HAM10000 |
- These are image-level classifiers, not detectors. They do not localise or stage disease; Grad-CAM is an explanation aid, not a segmentation.
- Datasets are modest and come from specific scanners and populations. Accuracy on your images will very likely be lower than the numbers above — that gap is the norm in medical imaging.
- Raw outputs are not calibrated — a "90%" score is not a 90% chance of cancer, and temperature scaling only partly fixes it (see the triage study). The rule-out bound is deliberately built not to depend on calibration.
- The rule-out guarantee holds only under exchangeability, which the KS check can refute but never confirm. A shift that preserves the score distribution while changing the risk-label relationship would pass it.
- Rule-out is evaluated at image level. Real screening decides per patient, across views and priors, and would need per-patient calibration units.
- Nothing here has been validated prospectively or reviewed by any regulator.
- The gate is tested against known foreign modalities. Inputs belonging to no medical modality at all are handled only by its confidence floor.
MammoAI — the breast-cancer counterpart: a deeper multi-stage system with clinical-feature fusion, SHAP explanations and calibrated ensembling.
MIT — see LICENSE.