Skip to content

[Bug]: get_pourbaix_entries with an r2SCAN user entry silently discards every r2SCAN entry, including the user's #1143

Open

Description

@kavanase

Code snippet

from collections import Counter

from mp_api.client import MPRester
from pymatgen.analysis.pourbaix_diagram import PourbaixDiagram
from pymatgen.entries.computed_entries import ComputedStructureEntry


def my_entry(mpr, formula, thermo_type):
    """MP's lowest-energy `formula` entry of `thermo_type`, as a user calculation 50 meV/atom lower in energy."""
    mp = min(
        mpr.get_entries(formula, additional_criteria={"thermo_types": [thermo_type]}),
        key=lambda e: e.energy_per_atom,
    )
    return ComputedStructureEntry(
        mp.structure,
        mp.uncorrected_energy - 0.05 * len(mp.structure),
        parameters=dict(mp.parameters),
        entry_id=f"my-{formula}-{mp.parameters['run_type']}",
    )


with MPRester() as mpr:
    print("MP database:", mpr.db_version)
    for formula, chemsys in (("TiO2", "O-Ti"), ("Fe2O3", "Fe-O")):
        for arg in (chemsys, [my_entry(mpr, formula, "GGA_GGA+U")], [my_entry(mpr, formula, "R2SCAN")]):
            pbx = mpr.get_pourbaix_entries(arg)
            ids = {str(e.entry_id) for e in pbx}
            solids = Counter(str(e.entry_id).rsplit("-", 1)[1] for e in pbx if e.phase_type == "Solid")
            stable = [(e.name, str(e.entry_id)) for e in PourbaixDiagram(pbx).stable_entries if e.phase_type == "Solid"]
            user = f"user entry {arg[0].entry_id}" if isinstance(arg, list) else "no user entries"
            returned = f" (returned: {arg[0].entry_id in ids})" if isinstance(arg, list) else ""
            print(f"{chemsys}, {user}{returned}: solids {dict(sorted(solids.items()))}")
            print(f"  Pourbaix-stable solids: {sorted(stable)}")

    # `solid_compat=None` keeps all entries, but leaves the user's raw r2SCAN energy off MP's mixed scale:
    pbx = mpr.get_pourbaix_entries([my_entry(mpr, "TiO2", "R2SCAN")], solid_compat=None)
    tio2 = sorted((round(e.entry.energy_per_atom, 3), str(e.entry_id)) for e in pbx if e.name == "TiO2(s)")
    print(f"O-Ti, solid_compat=None: lowest TiO2(s) formation energies (eV/atom): {tio2[:2]}")

What happened?

Since #990 (first released in v0.45.9), get_pourbaix_entries accepts user entries. If any of them is r2SCAN, it switches to the mixed GGA_GGA+U_R2SCAN thermo type:

user_run_types = {
entry.parameters.get("run_type", "unknown").lower()
for entry in user_entries
}
if any("r2scan" in rt for rt in user_run_types):
thermo_types = ["GGA_GGA+U_R2SCAN"]

I expect the desired behaviour is that each r2SCAN entry is placed on MP's mixed GGA(+U)/r2SCAN energy scale and included. Instead, however, every r2SCAN entry is silently discarded (MP's and the user's own). The diagram is then built from whatever GGA(+U) entries are left in MP's mixed hull. That leftover set has no entry at all for any material MP represents by its r2SCAN calculation.

Example of the issue from Claude:
Each user entry in the snippet below is a copy of MP's own lowest-energy entry, 50 meV/atom lower:

  • The r2SCAN user entry is not returned (returned: False). The GGA(+U) one is.
  • The reference solids get worse. Ti–O drops from 158 to 92 solids and Fe–O from 202 to 188, and higher-energy GGA(+U) polymorphs take the place of the ground states:
    • TiH2(s) becomes mp-1077353 (+219 meV/atom above the GGA(+U) hull);
    • TiO2(s) becomes mp-34688 (+8);
    • Fe(s) becomes mp-1271068 (+17).
  • The diagram is wrong. For Fe, the Pourbaix-stable solids change from Fe + Fe2O3 + FeO to Fe + Fe3O4 + FeHO2 + FeO. So an r2SCAN Fe2O3 entry that should stabilise Fe2O3 removes its domain instead. On a grid of pH 0–14 (step 0.5) × −2 to 2 V (step 0.1), the stable phase differs from the no-user-entry diagram at 431 of 1189 points for Fe–O, and at 25 for Ti–O.
  • No warning is raised. There are only INFO log lines (see Log output).

Origin: in the r2SCAN branch, get_pourbaix_entries fetches MP's pre-built mixed entries for the ion-reference system and appends the user's. The GGA(+U) entries carry MP2020 corrections; the r2SCAN entries carry MP GGA(+U)/r2SCAN mixing adjustments:

ion_ref_entries: Sequence[
ComputedEntry | ComputedStructureEntry | GibbsComputedStructureEntry
] = (
self.get_entries_in_chemsys(
list([str(e) for e in ion_ref_elts] + ["O", "H"]),
additional_criteria={"thermo_types": thermo_types},
# use_gibbs=use_gibbs
)
+ user_entries
)

It then applies MaterialsProjectAqueousCompatibility(solid_compat=MaterialsProject2020Compatibility()):

api/mp_api/client/mprester.py

Lines 987 to 1001 in f107e6d

compat = MaterialsProjectAqueousCompatibility(solid_compat=solid_compat)
# suppress the warning about missing oxidation states
n = len(ion_ref_entries)
with warnings.catch_warnings():
warnings.filterwarnings(
"ignore", message="Failed to guess oxidation states.*"
)
ion_ref_entries = apply_corrections(
compat,
ion_ref_entries,
description="Applying aqueous corrections",
log=f"Applying aqueous corrections to {n:,} ion reference entries",
summary=f"Applied aqueous corrections to {n:,} entries ({{kept:,}} kept)",
enabled=not self.mute_progress_bars,
)

That first re-applies solid_compat.process_entries(entries, clean=True) (pymatgen L1611-L1615), which strips the mixing adjustments. MP2020 then rejects every run type but GGA/GGA+U (L1084-L1088), and on_error="ignore" swallows the CompatibilityError (L633-L638).

For H–O–Ti, 225 entries go in (MP's 118 GGA and 106 r2SCAN entries, plus the user's) and 118 come out. test_get_pourbaix_entries only passes chemical systems, so the user-entries path is untested.

This is unchanged by the currently-open PRs or materialsproject/pymatgen#4754.

Suggested fix: in the r2SCAN branch, do what get_stability does, and re-mix MP's un-mixed GGA(+U) and r2SCAN entries together with the user's:

api/mp_api/client/mprester.py

Lines 1977 to 1986 in f107e6d

joint_entries: Sequence[ComputedEntry | ComputedStructureEntry | PDEntry] = [
*entries,
*(
self._get_unmixed_entries(_all_subchemsyses(str(el) for el in chemsys))
if thermo_type_valid_str == ThermoType.GGA_GGA_U_R2SCAN.value
else pd.all_entries
), # `pd.all_entries` for a mixed hull hold one already-mixed entry per material,
] # which the mixing scheme cannot re-process (needs the GGA(+U) and r2SCAN entries
# side by side), and silently drops every entry it cannot pair up -- so we fetch
# separately in the mixed case

Then don't re-apply MP2020, because the mixing scheme's compat_1 has already applied it:

ion_ref_elements = [str(e) for e in ion_ref_elts] + ["O", "H"]
if thermo_types == ["GGA_GGA+U_R2SCAN"]:
    MaterialsProjectDFTMixingScheme = mixing_scheme_class()
    ion_ref_entries = apply_corrections(
        MaterialsProjectDFTMixingScheme(run_type_2="r2SCAN", fuzzy_matching=False),  # as MP builds its hulls
        self._get_unmixed_entries(_all_subchemsyses(ion_ref_elements)) + user_entries,
        ...,
    )
    solid_compat = None  # MP2020 already applied (the scheme's compat_1); re-applying it drops r2SCAN
else:
    ion_ref_entries = self.get_entries_in_chemsys(
        ion_ref_elements, additional_criteria={"thermo_types": thermo_types}
    ) + user_entries

From testing, this fixes these issues.
However, there are some points that should probably be decided before implementing a PR (hence I'm raising an issue rather than PR here):

  • H2O reference: MaterialsProjectAqueousCompatibility infers h2o_energy and h2o_adjustments from the lowest-energy H2O entry (L1636-L1640).
    • In the re-mixed set, that entry is mp-697111-r2SCAN. Its only adjustment is its mixing adjustment (+0.151 eV/atom), against −0.229 eV/atom for the MP2020-corrected mp-697111-GGA.
    • As a result, the MP Aqueous hydrate adjustment (L1557) becomes +2.004 instead of +3.145 eV per H2O.
    • This makes no difference to the Ti or Fe diagrams here. Still, the fix should probably pass both values explicitly, since pymatgen only infers them when neither is given.
  • Other solid_compat values. Users can combine r2SCAN entries with a non-MP2020 solid_compat, including None, which has been valid since [Bug]: get_pourbaix_entries does not support solid_compat=None #1060/Allow solid_compat to be None in get_pourbaix_entries #1061. The mixing scheme is built on MP2020, so this combination should probably warn or raise? Separately, a user's own MP2020 instance would need passing on as compat_1.
  • Dropped user entries. A warning for user entries the corrections drop would also catch the same silent drop on the GGA(+U) path, e.g. for a ComputedEntry without parameters["run_type"]. get_stability: no hull energy for entries the corrections drop #1142 adds such a warning to get_stability.

Version

mp-api 0.47.0, pymatgen 2026.9.24, pymatgen-core 2026.10.16, emmet-core 0.88.0, Python 3.13.1; MP database 2026.09.28

Which OS?

  • MacOS
  • Windows
  • Linux

Log output

MP database: 2026.09.28
O-Ti, no user entries: solids {'GGA': 158}
  Pourbaix-stable solids: [('TiH2(s)', 'mp-24726-GGA'), ('TiO2(s)', 'mp-554278-GGA')]
O-Ti, user entry my-TiO2-GGA (returned: True): solids {'GGA': 159}
  Pourbaix-stable solids: [('TiH2(s)', 'mp-24726-GGA'), ('TiO2(s)', 'my-TiO2-GGA')]
O-Ti, user entry my-TiO2-r2SCAN (returned: False): solids {'GGA': 92}
  Pourbaix-stable solids: [('TiH2(s)', 'mp-1077353-GGA'), ('TiO2(s)', 'mp-34688-GGA')]
Fe-O, no user entries: solids {'GGA': 16, 'GGA+U': 186}
  Pourbaix-stable solids: [('Fe(s)', 'mp-13-GGA'), ('Fe2O3(s)', 'mp-19770-GGA+U'), ('FeO(s)', 'mp-1274279-GGA+U')]
Fe-O, user entry my-Fe2O3-GGA+U (returned: True): solids {'GGA': 16, 'GGA+U': 187}
  Pourbaix-stable solids: [('Fe(s)', 'mp-13-GGA'), ('Fe2O3(s)', 'my-Fe2O3-GGA+U'), ('FeO(s)', 'mp-1274279-GGA+U')]
Fe-O, user entry my-Fe2O3-r2SCAN (returned: False): solids {'GGA': 11, 'GGA+U': 177}
  Pourbaix-stable solids: [('Fe(s)', 'mp-1271068-GGA'), ('Fe3O4(s)', 'mp-31770-GGA+U'), ('FeHO2(s)', 'mp-696580-GGA+U'), ('FeO(s)', 'mp-1274279-GGA+U')]
O-Ti, solid_compat=None: lowest TiO2(s) formation energies (eV/atom): [(-5.517, 'my-TiO2-r2SCAN'), (-3.297, 'mp-390-r2SCAN')]

# the only other output for the O-Ti r2SCAN-user-entry call (in a terminal, the progress summary reads
# "Applied aqueous corrections to 225 entries (118 kept)"):
mp_api.client - INFO - Fetching the GGA_GGA+U_R2SCAN phase diagram for H-O-Ti...
mp_api.client - INFO - Applying aqueous corrections to 225 ion reference entries
# the reason, swallowed by `on_error="ignore"`:
>>> MaterialsProject2020Compatibility().get_adjustments(my_entry(mpr, "TiO2", "R2SCAN"))
CompatibilityError: Entry my-TiO2-r2SCAN has invalid run type r2SCAN. Must be GGA or GGA+U. Discarding.

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment